| OPTIZEN 3220UV BIO |
| DNA, RNA, and protein analyzer |
|
 |
|
Easy performances in biochemistry analysis.
1. No sample dilution
2. No other cuvettes
3. No cross contaminations
4. Good reproducibility
|
 |
 |
 |
 |
|
| |
Our Optizen Nanobiometer is designed for measure more accurate analysis of extremely small samples with remarkable reproducibility.
Optizen 3220UV BIO analyzes components with requirement of multiple wavelengths, time course operations, and getting stable data sheets.
Due to the integrated beam deflection and the use of fibre-optic cables it is possible to emasure the sample directly on the surface of the optical window. The cap with mirror provides a welldefined optical light path and prevents the sample from drying up or evaporated. Leads to much small volume to be analyzed. The measurement remains reproducible because the sample will not be enriched by evaporation of the solution. During filling and cleaning stages, cell remaining in the photometer leads to continuously identical position of the aperture in the light beam and no variation in comparison to the reference measurement. |
|
| |
| Features with performance and reliability |
| |
- Nucleic acids analysis
- Determination of the incorporation frequency of fluorescent dye labels ( FOI)
- Protein analysis : A280, BCA, Bradfod, Lowry and etc.
- All UV/Visible range utilized analysis
- Labeling efficiency
- Enzyme activity and reaction rate
- Cell density
|

Network environment with embedded personnel computer is already equipped analysis
|
| |
- User-friendly software with scanning and time course capacities.
- Versatile data processing.
It is even more powerful in information technologies so that you will be able to analyzer a wide range of samples and capable your analysis to put out experiments using programmed procedures, OPTIZEN 3220UV assures you and your lab partners stable, precise and reliable testing data. |
|
| |
| OPTIZEN View 4.1 (PC interface software) |
| |

|
ATC mode
Measuring absorption, transmittance, and concentration. |
 |
STC mode
Draw standard curve. |
 |
SUR mode
Making graph at the specific wavelength ranges. |
 |
KIN mode
Measurement with variable with time differences |
|
| |
Specifications
|
| |
Optizen Nanobiometer
double beam, Czerny-turner, 190-1100nm wavelength range approximately 1.00nm fixed spectral bandwidth, D2 lamp and tungsten lamp dual light sources with exceptionally long life and power saving, quartz overcoated optics, scan rates up to phase stepping wavelength drive, room light immunity, centrally controlled by embedded PC with Window interface.
|
| |
Photometrics system |
Double beam optics |
| |
Spectral bandwidth(nm) |
0.98 |
| |
Detector |
2 silicon diode detectors |
| |
accuracy(nm) |
0.03 at 656.1nm/ 0.28 at 486.0nm |
| |
scanning speed(nm/min) |
maximum 3000 |
| |
reproducibility(Abs) |
0.002 |
| |
1 second signal averaging time at 465nm
Maximum deviation at 1 Abs
Standard deviation for 10 measurements |
| |
stability(Abs/hour) |
30 minute warm up <0.002 |
| |
550nm, 1 second signal averaging time |
| |
Baseline flatness(Ans) |
30 minute warm up <0.002
|
| |
200 to 1100nm,smooth 30 applied, baseline corrected. |
| |
Lamp change wavelength |
340~410
|
| |
Default 370nm, include auto-positioning system |
| |
Recommended environmental conditions
|
| |
Instrument storage |
5 – 45at 20 to 80% relative humidity,
non-condensing, altitude < 2133m. |
| |
Instrument electrical requirements |
100/110/220/240 volts AC 10%, 50 or 60Hz
with 400VA power consumption. |
| |
Dimensions |
W600 X D440 X H250
|
| |
Weight |
16kg (Only main system) |
※Please contact our center overseas@mecasys.co.kr |
| |
◎ Optizen series are manufactured according to ISO-14001 as a certified quality system.
At your request on certificates,Calibration certificates, ISO 14001, CE, the origin of product can be
released by COMPANY. |
| |
|
|
| |
|
|
| |
|
|
|